Filter Results By:

Products

Applications

Manufacturers

Showing results: 256 - 270 of 393 items found.

  • Resistance Measurement

    PROMET - KoCoS Messtechnik AG

    High-precision micro-ohm measuring systems with adjustable DC test current for determining resistances on circuit breakers or inductive loads such as transformers, for example. The high-precision ohm meters of the PROMET series are used to determine very low electrical resistances in the µΩ range. The adjustable test current of up to 600 A in combination with a four-wire measuring method delivers measurement results which meet stringent accuracy requirements. State-of-the-art power electronics coupled with a robust design guarantee excellent reliability for use as a portable device in switching stations and industrial environments. Typical applications include determining the contact resistance of switchgear devices and determining the resistance on inductive loads such as transformers.

  • Onsite Mobile AC High Voltage Test System

    SGMF(T) Series - Shanghai Jiuzhi Electric Co., Ltd.

    Onsite mobile AC high voltage test systems are used for withstand voltage testing, partial discharge measurement, tan delta measurement to instrument transformers, GIS, GIL, switchgears and etc after they are installed onsite and for purposes of diagnostics in asset management up to 900kV/10A.

  • Single-Phase Transformer Winding Resistance Meters

    RMO-TD Series - IBEKO Power AB

    Using the most advanced switch-mode technology available today, the RMO-TD series is ideal for winding resistance measurements of inductive objects. Transformer resistance meters and tap changer analyzers are perfect for testing:transformer windings (power transformers, distribution, autotransformers),all types of tap changers,generators,electrical motors,high-current busbar joints,cable splices,and welding joints.In addition, transformer demagnetization can also be done with all RMO-TD instruments.The RMO-TD series contains 3 models, with maximal test currents from 25 A (RMO25TD) to 60 A (RMO60TD).The three independent voltage sense channels enable testing of three windings in series. This enables measurements of winding resistance in every tap position of an on-load tap changer without discharging between the tests.All RMO-TD transformer resistance meters have a built-in tap changer control unit. It enables remote control of on-load tap changer (OLTC) directly from the device. In order to make the most out of this feature, DV-Win software is included which can be programmed to do everything automatically – running winding resistance tests and changing OLTC tap positions.The DV-Win software also enables control and observation of the test process, as well as saving and analyzing the results on a PC. It provides a test report, arranged in a selectable form as an Excel spreadsheet, PDF, Word, or ASCII format. Additionally, DV-Win measures and calculates the OLTC transition time, the ripple and the winding resistance for each tap changing operation. The software can also perform the calculations necessary for the “Heat Run” test.All results can be exported in the report format.

  • Automatic Oil Tan Delta & Resistivity Kit

    MOTR - The Motwane Manufacturing Company

    Motwane's MOTR is multifunctional automatic test kit designed for accurate measurement of the Dielectric Constant, TanDelta, Resistivity & capacitance of transformer oil & other electrical insulating liquids. It has preprogrammed test sequences as per various International standards along with customized test sequences as per user requirements. Internal memory for 250 tests provided with PC interface & report generation facility. Inbuilt thermal printer for onsite results. Test cell is designed as per IEC247 with calibrator for onsite calibration of kit.

  • Computer Control 6-Phase Relay Protection Tester

    GDJB-PC6 - Chongqing Gold Mechanical & Electrical Equipment Co.,Ltd

    1.This tester with standard 6 phase voltage, 6 phase current output,2.Voltage 125V/phase, current 30A/phase, 6 phases in parallel can up to 180A.3.Digital Signal Processor Microcomputer.4.Not only test the traditional relays and protectors, but also test the modern micro computer replays, special for transformer differential protection and transfer equipments.

  • 10 A portable digital micro-ohmmeter

    MPK-253 - MEGABRAS srl

    The MPK-253 digital very low resistance ohmmeter is a portable, microprocessor-controlled instrument used to accurately measure resistances of switches and circuit breaker contacts, transformer and motor windings, wire and cable samples, joints in busbars, etc., using test currents from 1mA up to 10 A.

  • Primary Test Manager

    OMICRON electronics

    The Primary Test Manager™ (PTM) software supports you during diagnostic testing, condition assessment and data management of medium- and high-voltage assets, such as circuit breakers, rotating machines, grounding systems, instrument and power transformers as well as bushings and on-load tap changers (OLTC).

  • AC Resonant Test System

    Yangzhou Power Electric Co., Ltd

    Testing of certain apparatus requires much high voltage or current that a straight AC test system is not sufficient. Thus resonant test reactor with a variable core is needed. The main advantage of such test systems is lower input power and larger output power. The resonant test system is designed to compensate capacitance in the testing circuit precisely by tuning inductance of the test system. AC resonant test system is used for factory testing of middle, high and ultra-high voltage cables, capacitors, generators, motors, power transformers and gas-insulated switchgears.

  • HIPOT Insulation Testers

    Laycock Systems

    Crown high voltage, transformer type hipot insulation testers are safe, easy to use for quick, positive determination of grounds, shorts, and broken wires in motors, transformers and other low voltage equipment or wiring systems. A turn of the selector switch gives a selection of seven voltages; 500, 1080, 1250, 1500, 1750, 2000 or 2500 volts calibrated to +/- 5% accuracy; NEMA recommendation for insulation test is twice normal voltage plus 1000 volts. Since this instrument has a capacity of 2500 volts, it readily accommodates all normal requirements.

  • Partial Discharge Test Set

    NEO TELE-TRONIX PVT. LTD

    We are an unparalleled name in the industry, engaged in manufacturing and exporting Partial Discharge Test Set that is broadly used for instrument transformers to test the discharge of voltage. This test set is manufactured in compliance with set international quality standards using optimum quality components under the observations of our experienced professionals. Further, it is made available in several specifications to meet the exact requirements of the clients. Our offered Partial Discharge Test Set can be owned from us at nominal prices.

  • 5 A portable digital micro-ohmmeter

    MPK-254 - MEGABRAS srl

    The MPK-254 digital very low resistance ohmmeter is a portable, microprocessor-controlled instrument used to accurately measure resistances of switches and circuit breaker contacts, transformer and motor windings, wire and cable samples, joints in busbars, etc., using test currents from 1 mA up to 5 A.

  • Air Data Adapter Test Panel

    TA-241 - Tech-Aid Products

    AZ-241 Adapter Panel is designed to meet manufacturer's requirements. This panel will allow by the book testing of the air data computer when interfaced with the main air data test fixture. The Scott-T transformer is optional or can be customer supplied. Without the Scott-T your API can read the altimeter resolver directly.

  • Polarity Checker

    PW-VP50 - Ponovo Power Co., Ltd.

    PW-VP50 CT Polarity checker is the favorable meter which can be used for field CT and transformer polarity test in power plants, substations and any other application which may need to check the polarity. There are 2 units included in PW-VP50. One master machine which can automatically inject...

  • Regenerative AC Emulator, 600 VAC, 63 A, 30 KVA, 3‑Phase

    SL1201A - Keysight Technologies

    The SL1200A series was designed to handle all your 3-phase AC test needs up to 1200 VAC, from 30 kVA to 630 kVA without the need for a transformer. Two voltage ranges are available: 600 VAC and 1200 VAC. The 600 VAC models are ideal for low voltage inverter test as well as EV and EVSE charging test applications. The 1200 VAC models allow for (HVRT) testing at the IEC LV-AC limit without the need for a large, complex test setup.

  • Regenerative AC Emulator, 600 VAC, 63 A, 45 KVA, 3‑Phase

    SL1202A - Keysight Technologies

    The SL1200A series was designed to handle all your 3-phase AC test needs up to 1200 VAC, from 30 kVA to 630 kVA without the need for a transformer. Two voltage ranges are available: 600 VAC and 1200 VAC. The 600 VAC models are ideal for low voltage inverter test as well as EV and EVSE charging test applications. The 1200 VAC models allow for (HVRT) testing at the IEC LV-AC limit without the need for a large, complex test setup.

Get Help